Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. pharm. sci ; 51(4): 811-821, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778408

ABSTRACT

abstract Daptomycin is the first approved drug from a new class of antimicrobials, the cyclic lipopeptides, and is a very important antimicrobial agent in current clinical practice. Currently, there are no "green" analytical methods described in the literature to analyze the typical pharmaceutical dosage form of daptomycin. Thus, the aim of this work was to validate an environment-friendly spectrophotometric method in the UV region, for the analysis of daptomycin as a lyophilized powder. Water was used as diluent and the analyses were carried out on a spectrophotometer at 221 nm. The method met all validation requirements of the ICH guidelines, over a concentration range of 6-21 µg mL-1. A Student's t-test demonstrated that the proposed method was comparable to an HPLC method previously validated. Thus, the validated spectrophotometric method could quantify daptomycin in a powder form for injectable solutions, while being an economical, rapid, and "green" alternative for routine analysis in quality control.


resumo A daptomicina é o primeiro membro aprovado de uma nova classe de antimicrobianos, os lipopeptídeos cíclicos, e é muito importante para a prática clínica atualmente. Não existem métodos analíticos "verdes" descritos na literatura para a análise da daptomicina na forma farmacêutica. Desta forma, o objetivo deste trabalho foi a validação de método espectrofotométrico na região do UV ambientalmente favorável para análise da daptomicina em pó liofilizado. A água foi escolhida como diluente e as análises foram realizadas em 221 nm. O método atendeu a todas as exigências de validação dos guias do ICH, na faixa de 6-21 µg mL-1. Teste t de Student mostrou que o método proposto é intercambiável com método de HPLC previamente validado. Assim, o método espectrofotométrico validado é capaz de quantificar a daptomicina em pó para solução injetável e é uma opção econômica, rápida e "verde" para análises de rotina do controle de qualidade deste fármaco.


Subject(s)
Spectrophotometry, Ultraviolet , Chemistry, Pharmaceutical/classification , Daptomycin/analysis , Quality Control , Anti-Infective Agents/analysis
2.
Braz. j. pharm. sci ; 51(3): 629-635, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766314

ABSTRACT

Norfloxacin is one of the first commercially available (and most widely used) fluoroquinolone antibiotics. This paper reports the development and validation of a simple, sensitive, accurate and reproducible turbidimetric assay method to quantify norfloxacin in tablets formulations in only 4 hours. The bioassay is based on the inhibitory effect of norfloxacin upon the strain ofStaphylococcus epidermidis ATCC 12228 IAL 2150 used as test microorganism. The assay was performed 3x3 parallel lines like, three tubes for each concentration of reference substance and three tubes for each sample concentration. The results were treated statistically by analysis of variance and were found to be linear (r2 = 0.9999) in the selected range of 25-100 μg mL-1; precise (intra-assay: relative standard deviation (RSD) = 1.33%; inter-assay: RSD = 0.21%), accurate (100.74%) and robust with RSD lower than 4.5%. The student's t-test showed no statistically significant difference between the proposed turbidimetric method and an HPLC method previously validated. However the turbidimetric assay can be used as a valuable alternative methodology for the routine quality control of this medicine, complementary to other physical-chemical methods.


O norfloxacino foi a primeira fluorquinolona (e mais utilizada) disponível no mercado. Este trabalho divulga um novo desenvolvimento e validação de um método turbidimétrico simples, sensível, preciso e reprodutível para a quantificação de norfloxacino em comprimidos em apenas 4 horas. O bioensaio é baseado no efeito inibitório de norfloxacino sobre a cepa Staphylococcus epidermidis ATCC 12228 IAL 2150, utilizada como micro-organismo teste. O bioensaio foi efetuado através do delineamento de linhas paralelas 3x3, em que três tubos foram utilizados para a solução padrão e três tubos para as concentrações da amostra. Os resultados foram tratados estatisticamente pela análise de variância, apresentando coeficiente de correlação linear der2 = 0,9999, na faixa de 20 a 100 μg mL-1; precisão (intra-ensaio: desvio padrão relativo (RSD) 1,33%; inter-ensaio: RSD=0,21%), exatidão (100,74%) e robustez com RSD menor que 4,5%. O teste-tmostrou não haver diferença estatisticamente significativa entre o método turbidimétrico proposto e um método por HPLC previamente validado. No entanto, o ensaio turbidimétrico pode ser utilizado como método alternativo para o controle de qualidade de rotina para este antimicrobiano, como um complemento de outros métodos físico-químicos.


Subject(s)
Norfloxacin/pharmacokinetics , Validation Study , Nephelometry and Turbidimetry , Quality Control , Tablets/pharmacokinetics , Anti-Infective Agents/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL